Pundit ultrasonic pulse velocity and pulse echo tomography

Models

Pundit Live Array Pro
Pundit Lab(+)
Pundit 200
Pundit 200 Pulse Echo
Pundit 250 Array

Descriptions

The wireless Pundit Live Array Pro tomography scanner is connected with an iOS app to an Apple® iPad. It comes with Artificial Intelligence (A.I.) user support and 3D imaging capabilities.

The Pundit Lab is a flexible UPV test instrument designed primarily for operation in laboratories. It supports all traditional UPV test modes. The Pundit Lab+ comes with an extended feature set. 

The Pundit 200 is a best-in-class UPV test instrument with an extended range of measurement modes. Rugged touchscreen with intuitive user interface for best possible measuring and analysis of the measured data. 

The Pundit 200 Pulse Echo extends the ultrasonic application to objects where access is restricted to a single side. Major applications are slab thickness measurments and the location of voids and delaminations. Rugged touchscreen with intuitive user interface. 

The Pundit 250 Array tomography scanner is perfect for thickness measurements, localization of defects and detection of objects in concrete and fibre reinforced concrete. It features real-time B-Scans and a panorama mode.

Your Benefits

Real-time tomography  Real-time tomography
 
Smart A.I. user support and positioning  Smart A.I. user support and positioning
 
Increased productivity  Increased productivity
Automated combination of the transmitter voltage and the receiver gain for accurate and stable measurements  Automated combination of the transmitter voltage and the receiver gain for accurate and stable measurements
 
Open interface, can be integrated into LabView  Open interface, can be integrated into LabView
 
Pundit Lab+ removes the need for external amplification when used with exponential transducers  Pundit Lab+ removes the need for external amplification when used with exponential transducers
 
 
Various measurement modes including Line Scan, Area Scan, Data Logging, compressive strength correlations and E-modulus measurement  Various measurement modes including Line Scan, Area Scan, Data Logging, compressive strength correlations and E-modulus measurement
 
Automatic surface velocity calculation according to standards  Automatic surface velocity calculation according to standards
 
Same instrument can be used with pulse echo transducers  Same instrument can be used with pulse echo transducers
B-Scan is constructed directly on the instrument as the scan is carried out  B-Scan is constructed directly on the instrument as the scan is carried out
 
Can be upgraded to Multi Channel  Can be upgraded to Multi Channel
 
Same instrument can be used with classic pulse velocity transducers  Same instrument can be used with classic pulse velocity transducers
Real-time B-scan and panorama mode for extended scans of several meters  Real-time B-scan and panorama mode for extended scans of several meters
 
Single handed positioning with upgrades to double handle and 16 channels for large area scans  Single handed positioning with upgrades to double handle and 16 channels for large area scans
 
High resolution of defects, rebars and tendon ducts with superior near field performance  High resolution of defects, rebars and tendon ducts with superior near field performance

Measuring Range

>1 m depending on concrete quality
Up to 15 m depending on concrete quality
Up to 15 m depending on concrete quality
Up to 1 m depending on concrete quality

Up to 1 m depending on concrete quality

Bandwidth

15 to 100 kHz
20 to 500 kHz
20 to 500 kHz
20 to 500 kHz

15 to 100 kHz

Technology

Phased array ultrasonic pulse echo
Ultrasonic pulse velocity
Ultrasonic pulse velocity
Single channel ultrasonic pulse echo

Phased array ultrasonic pulse echo

Measuring Resolution

1 μs
0.1 us
0.1 us
0.1 us

1 μs

Pulse Voltage UPV

125 to 500 V
100 to 450 Vpp

Pulse Voltage UPE

± 50 to ± 200 V

±150 V

Receiver Gain

1 to 10’000x (0 to 80 dB)

1x, 10x, 100x, AUTO, Pundit Lab+ up to 1000x
1 to 10’000x (0 to 80 dB)
1 to 10’000x (0 to 80 dB)

1 to 10’000x (0 to 80 dB)

Nominal transducer frequency

50 kHz shear wave

24 – 500 kHz
24 – 500 kHz
24 – 500 kHz

50 kHz shear wave

Pulse Shape

Square wave

Square wave
Square wave
Square wave

Square wave

Pulse Delay

8 ms – 200 ms

8 ms – 200 ms

Number Of Channels

8 (with upgrade option to 16)

1
1
1

8 (with upgrade option to 16)

Applications

Pundit Live Array Pro
Pundit Lab(+)
Pundit 200
Pundit 200 Pulse Echo
Pundit 250 Array

Pulse velocity determination

Quality assessment and uniformity

Compressive strength estimation

Pundit Lab+ only

SONREB

Pundit Lab+ only

Modulus of elasticity measuremen

Curing status evaluation

Thickness measurement from a single side

Crack depth estimation

Location of delaminations, voids and honeycoming

Location of hollow pipes

Location of pipes and tendon ducts beyond the rebar layer

Assessment of fibre reinforced concrete

Additional Applications

Chocolate molds

Mass rapid transportation

Crack depth

Asphalt healing process

Large pillar

Cultural relics

Underwater structures

Refractory material

Epoxy in wind industry

SONREB – combining Pundit and RockSchmidt

Underwater bridge pier

NDT of rock reference list

Prefabricated walls

Refractory

Ignoring small bar reinforcement

Wall cavity insulation beads

Concrete slab thickness

Post tensioning cables

Delamination spotting

Voids

Minimum ground floor thickness

SONREB – combining Pundit and RockSchmidt

Pre-casted subway station elements

Ultrasonic concrete thickness measurement

Honeycomb detection

Features

Pundit Live Array Pro
Pundit Lab(+)
Pundit 200
Pundit 200 Pulse Echo
Pundit 250 Array

Instrument Firmware

High resolution imaging of thickness variations, delaminations, voids and tendon ducts

Cursors for depth and horizontal displacement information

Settings directly accessible on measuring screen

AI positioning system

Automatic back wall detection

Automatic pulse velocity estimation

Open interface

Integrated amplifier gain stage (Pundit Lab+ only)

Real time stamp (Pundit Lab+ only)

Zoom and scroll for precise A-Scan inspection

On board storage and review of waveforms

Settings directly accessible on measuring screen

Dual cursor for manual A-Scan evaluation

Separate cursor to measure signal amplitude

Automatic and manual triggering and user adjustable trigger threshold

A-Scan update rate up to 25 Hz

Gate function

Raw data export

Settings directly accessible on measuring screen

Advanced echo tracking technology helps identifying the main echo

Automatic estimation of the Pulse Velocity

High resolution imaging of defects, rebars and tendon ducts

Cursors for depth and horizontal displacement information

Settings directly accessible on measuring screen

Raw data export

PC Software

Browser-based live.proceq.com webtool

Pundit Link unlocks the full Pundit Lab+ capabilities

PL-Link for analysis and export data to third party applications

PL-Link for analysis and export data to third party applications

PL-Link for analysis and export data to third party applications

Display

Any compatible Apple® iPad (iOS 9.0 and higher)

79 x 21 mm passive matrix OLED

7” color rugged touchscreen unit (800 x 480 pixels) with dual core processor

7” color rugged touchscreen unit (800 x 480 pixels) with dual core processor

7” color rugged touchscreen unit (800 x 480 pixels) with dual core processor

Memory

Up to 512 GB (depending on the Apple® iPad model)

> 500 measured values

Internal 8 GB flash memory

Internal 8 GB flash memory

Internal 8 GB flash memory

Connections

Wi-Fi connection to Apple® iOS tablet, USB port for Wi-Fi module

USB connection to PC

USB host / device and Ethernet

USB host / device and Ethernet

USB host / device and Ethernet

Measurement Modes

A-scan

Line scan

Pulse velocity

Surface velocity

Data logging

E-modulus

Compressive strength correlation (Pundit Lab+ only)

Crack depth

Pulse velocity

Surface velocity

Data logging

E-modulus

Compressive strength correlation

Crack depth

Line Scan

Area Scan

Pulse velocity

Area Scan

A-Scan

B-Scan

Distance

A-scan

Real-time B-scan

Panorama B-scan

Transducers

Rugged, compact and lightweight Pundit Array Transducer. Standard: Single handed transducer. Dual handle upgrade for increased control (buttons on both handles, optimize gain settings and trigger a measurement). Upgrade to 16 channels for double the scan width

Avaiable Proceq transducers: 54 kHz, 150 kHz, 250 kHz, 54 kHz Exponential, 500 kHz and 250 kHz Shear Wave

Connect third party transducers up to 500 kHz with BNC connector

Avaiable Proceq transducers: 54 kHz, 150 kHz, 250 kHz, 54 kHz Exponential, 500 kHz and 250 kHz Shear Wave

Connect third party transducers up to 500 kHz with BNC connector

Dry-contact Pundit Pulse Echo transducer with control buttons, optical feedback, center marker and rulers for easy B-Scan measurements

Avaiable Proceq transducers: 54 kHz, 150 kHz, 250 kHz, 54 kHz Exponential, 500 kHz and 250 kHz Shear Wave

Connect third party transducers up to 500 kHz with BNC connector

Rugged, compact and lightweight Pundit Array Transducer. Standard: Single handed transducer. Dual handle upgrade for increased control (buttons on both handles, optimize gain settings and trigger a measurement). Upgrade to 16 channels for double the scan width

Standardization

Pundit Live Array Pro
Pundit Lab(+)
Pundit 200
Pundit 200 Pulse Echo
Pundit 250 Array

Standards

  • EN 12504-4
  • ASTM C 597-02
  • ISO 1920-7:2004
  • IS 13311
  • CECS 21
  • ГОСТ 17624
  • EN 12504-4
  • ASTM C 597-02
  • ISO 1920-7:2004
  • IS 13311
  • CECS 21

Guidelines

  • RI-ZFP-TU
  • FCC Part 15: 2010
  • Class A Digital Device
  • RI-ZFP-TU
  • RI-ZFP-TU
  • FCC Part 15: 2010
  • Class A Digital Device

Accessories

Pundit Live Array Pro
Pundit Lab(+)
Pundit 200
Pundit 200 Pulse Echo
Pundit 250 Array

Measurement Accessories

Upgrade to 16 channel: Pundit Array Transducer (327 30 100), Pundit Array Transducer Extension Kit (376 30 377) and Dual Handle Kit (327 30 370)

Upgrade to dual handle: Dual Handle Kit (327 30 370)

Pundit Array Transducer Battery Pack Complete (327 30 337)

Rechargeable AA NiMH battery set of 6 (327 30 384S)

Calibrated tape set of 5 (327 01 071S)

2 S-Wave Transducers, 250 kHz, incl. couplant (325 40 049)

2 Exponential transducer 54 kHz, including calibration rod (325 40 176)

Transducer 150 kHz (Two required for operation) (325 40 141)

2 S-Wave Transducers, 250 kHz, incl. couplant (325 40 049)

2 Exponential transducer 54 kHz, including calibration rod (325 40 176)

Pundit Pulse Echo Transducer, incl. cable, contact tester and documentation (327 40 130)

Upgrade Kit to Pundit 250 Array (327 30 130)

Battery complete (327 01 033)

Quick Charger (external) (327 01 053)

Pundit® Dry-Point Shear Wave Transducer

Upgrade Kit to Pundit® 250 Array (327 30 130)

2 S-Wave Transducers, 250 kHz, incl. couplant (325 40 049)

2 Exponential transducer 54 kHz, including calibration rod (325 40 176)

Battery complete (327 01 033)

Quick Charger (external) (327 01 053)

Upgrade to 16 channel: Pundit Array Transducer (327 30 100), Pundit Array Transducer Extension Kit (376 30 377) and Dual Handle Kit (327 30 370)

Upgrade to dual handle: Dual Handle Kit (327 30 370)

Pundit Array Transducer Battery Pack Complete (327 30 337)

Rechargeable AA NiMH battery set of 6 (327 30 384S)

Calibrated tape set of 5 (327 01 071S)

Battery complete (327 01 033)

Quick Charger (external) (327 01 053)

 

 

Scroll to Top