DSX CableAnalyzer™ Series Copper Cable Certifiers

Accelerates every step of the copper certification process

  • Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  • Unmatched speed for Cat 6A, 8, Class FA, I/II and all current standards
  • ProjX™ system manages job requirements and progress from set-up to systems acceptance, making sure all tests are completed correctly
  • Taptive™ user interface simplifies set-up, and eliminates errors
  • Analyze test results and create professional test reports using LinkWare™ management software
  • Graphically displays the source of failures including crosstalk, return loss and shield faults for faster troubleshooting
  • Intertek Verified to TIA Level 2G – the most stringent accuracy requirement
  • Copper cable certifiers endorsed by cabling vendors worldwide
  • Built in Alien Crosstalk testing capability
  • Compatible with Linkware™ Live. Linkware Live enables to easily track job progress, get real-time access to test results to quickly fix problems in the field, and easily transfer and consolidate test results from the tester to LinkWare™ PC Cable Test Management Software.

OVERVIEW

The DSX CableAnalyzer Series copper cable certifiers enables testing and certification of twisted pair cabling for up to 40 Gigabit Ethernet deployments and will handle any cabling system whether it is a Cat 5e, 6, 6A, 8 or Class FA and I/II. Certifying a cable is one part of a process that starts with system design and ends with system acceptance. The faster that process goes, the more profitable you’ll be. Unfortunately, there are a lot of things that slow the process down – setting up the tester incorrectly, testing to the wrong limits, waiting for skilled technicians to analyze and troubleshoot failures, misinterpretation of results, and producing test reports that customers cannot understand.

As part of the Versiv cabling certification product family, the DSX CableAnalyzer Series copper cable certifiers provides accurate, error-free certification. In the installation business there are multiple teams, varying media types and multiple testing requirements. The difference between being profitable or not is just a few percentage points. The DSX certifies copper cabling, complies with all standards including Level VI/2G accuracy, making jobs easier to manage, and getting to system acceptance faster. It’s not just for the expert technicians and Project Managers. Individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects.

FEATURES

The DSX CableAnalyzer Series family copper cable certifier is based on two modules: the DSX-5000 and DSX-8000. The DSX-5000 certifies twisted pair Cat 5e, 6, 6A and Class FA cabling with limits up to 1000 MHz. The DSX-8000 certifies twisted pair Cat 5e, 6, 6A, 8 and Class I/II cabling with limits up to 2000 MHz.

 Copper Certification
 DSX-8000 CableAnalyzer™DSX-5000 CableAnalyzer™
Category 6A / Class EA test time8 seconds10 seconds
Category 8 / Class I/II test time15 seconds 
HDTDX/HDTDR diagnostic test times≈ 3 seconds≈ 3 seconds
Internal memory≈ 5,000 Cat 8 with plots
≈ 12,000 Cat 6A with plots
≈ 12,000 Cat 6A with plots
Level V Accuracy (1 GHz)
Level VI/2G Accuracy (2 GHz) 
Resistance Unbalance measurement
Shield integrity check
TCL measurement
ELTCTL measurement
CDNEXT measurement
CMRL measurement
Built in Alien XTalk module
Channel Adapter2 GHz Range1 GHz Range
Permanent Link Adapter2 GHz Range1 GHz Range
Optional Accessories
Patch cord adaptersCategory 5e, 6 and 6A patch cordCategory 5e, 6 and 6A patch cord
Coax Adapter
M12 Adapter
TERA Adapter
GG45 Adapter

Unique Features:

  • Versiv enables users to accomplish more than ever before with a cable tester, by accelerating every step of the testing process
  • LinkWare Live cloud service lets the Project Manager remotely set up the testers, monitor job progress and even location from any smart device
  • ProjX™ management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
  • Taptive™ user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
  • LinkWare PC management software provides unmatched analysis of test results and professional test reports
  • The DSX reduces the time required to fix cabling faults with dedicated diagnostics, a simple test that locates the problem

Standards:

  • Compliant with ANSI/TIA-1152-A Level 2G and proposed standard IEC 61935-1 Ed. 5 Level VI field tester accuracy requirements to 2000 MHz
  • Supports the complete suite of Resistance Unbalance standards needed for Power over Ethernet (PoE) –IEEE 802.3bt, ANSI/TIA/EIA-568, ISO/IEC 11801 series documents
  • TCL and ELTCTL measurements compliant to IEC 61935-1-1 (Draft)
  • Screen continuity along path of cabling

Performance:

  • Eight second Cat 6A test time contributes to the fastest way to gain certification
  • Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting
  • Manage up to 12,000 Cat 6A test results with full graphics
  • Capacitive touchscreen allows quick tester setup with easily selectable cable types, standards and testing parameters
  • Integrated Wi-Fi allows you to easily upload results to LinkWareTM Live
  • Over 1 billion links reported on LinkWare PC management software

Manage up to 12,000 Cat 6A test results with full graphics

Managing the testing of multiple jobs with multiple teams, testers, and requirements is time consuming and a source of errors. Increasingly larger jobs make project organization more important than ever. The new ProjX management system on the DSX CableAnalyzer Series copper cable certifiers provides individual project files for all job specific details to be saved under a simple name, eliminating the need to re-enter job specific details after starting a project. This minimizes set-up errors or lost files when switching from one job to another or utilizing multiple testers on a single job. In addition, it provides test results by cable ID, merges any changes without duplicates and defaults to the last copper or fiber module installed. ProjX management system provides real time status to completion on each job with a 0-100% scale and gives the operator the option to isolate any test requiring a second look and helps to assure nothing is overlooked. The “Fix Later” selection creates a punch list or automatic to do list for correcting any workmanship issues. ProjX enables project managers and crew leaders to be truly efficient.

 

 

Project Setup screen 

Project menu screen shows 
percent complete per job.
Arrow
Project Menu Screen 

Specific screen shows up to the minute project details.
Arrow
Project Test Setup Screen 

Set-up or view test limits, and 
testing attributes.

Capacitive touchscreen allows quick tester setup and supports all standards

Taptive user interface is easy enough for even the newest technician to perform tests across multiple media types and testing requirements. The capacitive Taptive user interface makes all jobs easily accessible from the menu screen. Touch the job you’re working on and the large display confirms the test that needs to be performed, animated instructions simplify setting the configuration making correct testing assured.

 

Taptive User Interface Screen
Simple Set up.

 

Eight second Cat 6A test time and the fastest way to submit your certification results

No tester offers so much speed for so many tests. Complete copper certification to Cat 6A in 8 seconds or certify two fibers at two wavelengths in just 3 seconds. Endorsements by cabling vendors worldwide assure that Versiv is the fastest way to project completion and system acceptance. Quickly get a Pass or Fail result and easily review individual test parameters by value or drill into specific area on a graph.

Passing Test Results

There may be scenarios where a typical four-connector channel is not used when connecting these types of devices– especially those that reside in the ceiling space where it is impractical to install a faceplate. Instead, there is just one patch cord in the telecommunications room and the permanent link is terminated at the other end with a plug so it can plug directly into the device, essentially eliminating the equipment cord. This creates what is now known as a Modular Plug Terminated Link, or MPTL.

The DSX CableAnalyzer™ is capable of certifying MPTL by using a patch cord adapter on one end and a permanent link on the opposite end (see image below).

The patch cord adapters support Category 5e, 6, and 6A performance levels and work with all DSX CableAnalyzer™ models. The latest version of the Versiv/DSX firmware is required to use the MPTL testing limits.

LinkWare Live is a cloud-based service that lets you manage certification jobs anytime, anywhere, with anyone on any device.  With LinkWare Live, you can

  • Keep track of every test on every job.  Get an overview of every project from any smart device. Drill down to each individual test. Instantly receive notification of incorrect test setting or cable IDs.
  • Get it right the first time. Define cable IDs and test settings from your PC or tablet. Then send them to the testers or Brother printers at the jobsite for mistake-free testing and labeling.
  • Keep your testers up to date. Standards can change without notice, and an out-of-date test report can mean hours of re-testing. LinkWare Live automatically ensures your testers are running the latest.
  • Stop wasting time and gas driving testers back to the office. Integrated Wi-Fi allows you to upload your test results straight from the job site to LinkWare Live. Then download them automatically to the right job for fast report generation with LinkWare PC.
  • Avoid Project Delays. Track the last used location and monitor the status of all testers to ensure they are always calibrated and running the latest firmware*
  • Supports all Versiv models: DSX CableAnalyzer Series, CertiFiber Pro, OptiFiber Pro, and the FI-7000.

*See supported countries.

LinkWare Live Test Result Screen for St. Peter Hospital     LinkWare Live Test Result Dashboard Screen

Leveraging the popular and multi-featured LinkWare PC management software application, DSX CableAnalyzer Series users can easily access the ProjX management system data, generate reports, and upgrade the software in their testers. Project Managers have full capabilities to manage workflow and consolidate test results. Users can provide the finishing touch by adding their company logo to the report and offer it unaltered to their customers for system acceptance purposes. Keep your business tools simple, no matter which Fluke Networks copper or fiber tester you are using, LinkWare PC is the software package that reports it all.

Now with LinkWare PC stats, the new automated statistical report option, you can move above and beyond the page-per-link report and see your entire cabling infrastructure. It analyzes and transforms LinkWare PC test results data into charts and diagrams that reveal your cabling plant performance; this report summarizes your entire cabling infrastructure in a compact, graphical format that makes it easy to verify margins and to spot anomalies.

LinkWare™ PC Cable Test Management Software Screen LinkWare Stats Screen
New versions of LinkWare PC are always backwards compatible with previous versions, so you can stay current and always integrate tests from different testers into one test report. LinkWare Stats summarizes all project data

Electrically centered plug design is compliant with TIA Level 2G and IEC Level VI accuracy requirements to 2000 MHz with a future-ready design to support all hardware upgrades

The DSX CableAnalyzer Series enables cable testing and certification for network deployments up to 40 Gigabit Ethernet – whether it is an existing Cat 5e, 6, 6A, 8 or Class I/II cabling system, the DSX tests to all industry standards. The electrically centered test plug results in the Level 2G/VI accuracy required to support field testing to Cat 8 / Class I/II, 2000 MHz. The DSX exceeds the IEC Level VI and TIA Level 2G specifications assuring you of higher confidence in results over the full frequency range. Higher performance cabling systems like Cat 8 require more precise measurement to ensure they are providing the noise immunity required by 25G and 40G applications. Additionally, complex Alien Crosstalk link-to-link certification is simplified by integrating the measurement capability into each copper module up to 40GBASE-T testing.

The DSX is the first field tester to support balance measurements including Transverse Conversion Loss (TCL) and Equal Level Transverse Conversion Transfer Loss (ELTCTL). TCL and ELTCTL are important measurements found in the cabling standards. They define a minimum performance for balance, a key parameter to help determine noise immunity. Industrial network owners/operators are especially interested in this property due to the higher level of electromagnetic interference (EMI) within the industrial environment.

Fluke Networks’ DSX CableAnalyzer Series has obtained Intertek (ETL) verification in accordance with the ANSI/TIA-1152-A specification for Level 2G test equipment. (Report on file.)

TLC and ELTCTL Graph View

Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting

The DSX reduces the time required to fix cabling faults with dedicated diagnostics, a simple 1 button test runs all tests and saves all data. The graphical results screen allows you to look down the cable to see exactly where any cross talk, return loss or shield faults are located on any given link. Previous testers had frequency limits of their diagnostic capabilities of up to 250 MHz only, but the DSX CableAnalyzer Series removes this limitation. This common view is easily interpreted by novice and expert users alike to isolate and act on any failed results quickly and is stored with the test result for remote analysis.

HTDTX shows the far end connection is clearly the issue 

High Definition Time Domain Crosstalk (HTDTX) shows the far end connection in clearly the issue
 Feature Simple Diagnostics
Features simple diagnostics based decades
of Fluke Networks troubleshooting experience.

Shield continuity historically is a direct current (DC) measurement with no distance to fault available. Other testers run a simple resistance test to verify that the shield has continuity. These tests have been shown to be inaccurate, sometime confusing a ground path as shield continuity and not correctly identifying a break in the shield. Other testers may tell you there is a break in a shield, but not pinpoint the exact location giving no indication of where to start rework. The DSX CableAnalyzer Series is the first field tester to report distance to any shield integrity issues, reporting the true status of the screen continuity. This is especially important in\ datacenters and Cat 8 installations where screen continuity is critical to maintaining alien crosstalk performance of screened cabling.

Wiremap Shows Distance to fault, break and short
Wiremap – shows distance to fault, break and short
Accessories
Model Number/NameDescription
DSX-8000 Accessories
 
DSX-PLA804SDSX-8000 Cat 8/Class I PLA Set. See Photo
DSX-CHA804SDSX-8000 Cat 8/Class I CHA Set. See Photo
DSX-8-TERA-KIT

DSX-8000 TERA PERMANENT LINK AND CHANNEL ADAPTER SET See Photo

DSX-CHA-8-GG45-SDSX-8000 GG45/ARJ45 Channel Adapter Set (2 GHz)
DSX-CHA-8-TERA-S

DSX-8000 TERA CHANNEL ADAPTER SET See Photo

DSX-PLA-8-TERA-S

DSX-8000 TERA PERMANENT LINK ADAPTER SET See Photo

DSX-PLA804-RKIT

DSX-PLA804 Plug replacement parts. This item includes two contact blocks of the 8-pin modular plug.

DSX-REFCAL2G

DSX-8000 2GHz Set-Ref Module

DSX-5000 Accessories
 
DSX-PLA001

DSX Universal Permanent Link Adapter See Photo

DSX-PLA004

SINGLE DSX CAT 6A/CLASS EA PERMANENT LINK ADAPTER

DSX-PLA004S

DSX CAT 6A/CLASS EA PLA SET See Photo

DSX-PLA004-RKIT

DSX-PLA004 plug replacement parts. This item includes two contact blocks of the 8-pin modular plug

DSX-PLA011S

DSX TERA CAT 7A/CLASS FA PLA SET See Photo

DSX-CHA004S

DSX CAT 6A/CLASS EA CHA SET See Photo

DSX-CHA011S

DSX TERA Cat 7A/CLASS FA CHA SET See Photo

DSX-TERA-KITDSX TERA CAT 7A/CLASS FA PLA & CHA KIT
DSX-CHA-5-GG45-SDSX-5000 GG45/ARJ45 Channel Adapter Set (1 GHz)
DSX-5000 MOD1 GHZ DSX Replacement MODULE
DSX-REFMODDSX-5000 SET-REF MODULE
Accessories for the DSX 5000/8000 CableAnalyzers
 
DSX-PC5ESingle Patch Cord Adapter for testing Cat 5e Modular Plug Terminated Links See Photo
DSX-PC6Single Patch Cord Adapter for testing Cat 6 Modular Plug Terminated Links See Photo
DSX-PC6ASingle Patch Cord Adapter for testing Cat 6A Modular Plug Terminated Links See Photo
DSX-COAX

DSX COAX ADAPTER SET

DSX-CHA021S

DSX M12 4-POSITION ADAPTER SET See Photo

DSX-CHA003

DSX COAX ADAPTER See Photo

DSX-PC5ES

DSX Patch Cord Test Adapter Set for Category 5e patch cords See Photo

DSX-PC6S

DSX Patch Cord Test Adapter Set for Category 6 patch cords See Photo

DSX-PC6ASDSX Patch Cord Test Adapter Set for Category 6A patch cords
DSX-PCTA5EKSSET OF TWO SHIELDED CAT 5E REPLACEMENT PATCH CORD JACKS
DSX-PCTAC6KSSET OF TWO SHIELDED CAT 6 REPLACEMENT PATCH CORD JACKS
DSX-PCTAC6AKSSET OF TWO SHIELDED CAT 6A REPLACEMENT PATCH CORD JACKS
VERSIV2-MVERSIV2 MAIN REPLACEMENT W/WIFI
VERSIV2-RUVERSIV2 REMOTE REPLACEMENT
VERSIV-CASE3

VERSIV Hardsided Case See Photo

VERSIV-LG-CASE

Versiv Large Carry Case See Photo

VERSIV-SM-CASE

Versiv Small Carry Case. See Photo

VERSIV-BACKPK-STRP

Backpack strap for Versiv Large Case See Photo

DSX-USB-CBLUSB INTERFACE CABLE STANDARD A TO MICRO B
PWR-SPLY-30W30W Power Supply, 15V, 2A with US adapter. See Photo
PWR-SPLY-30W INTL

30W Power Supply, 15V, 2A with US, EU, AU, and UK adapters See Photo

PWR-SPLY-30W SA/IN

30W Power Supply, 15V, 2A with US, South Africa and India adapters See Photo

PWR-SPLY-ADPEU, AU, UK adapters for 30W power supply. See Photo
PWR-SPLY-ADP-SA

South Africa and India adapters for 30W power supply See Photo

VERSIV-ADP-WIFI

WiFi Adapter for Versiv Mainframe. (Available in the following countries.)

VERSIV-TSET

Versiv Headphones See Photo

VERSIV-BATTERY

Versiv Battery See Photo

VERSIV-STRP

Versiv Strap Kit See Photo

VERSIV-STNDVersiv Demo Stand

SPECIFICATIONS

Cable Types
Shielded and unshielded pair LAN cablingTIA Category 3, 4, 5, 5e, 6, 6A, 8: 100 Ω
ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω
Standard Link Interface Adapters
Permanent link adaptersPlug type: shielded RJ45
Optional Plug type: Tera
Channel AdaptersJack type: shielded RJ45
Optional Jack type: Tera, GG45
Test Standards
TIACategory 3, 4, 5, 5e, 6, 6A, 8 per TIA 568-C.2
ISO/IECClass C and D, E, EA, F, FA and I/II certification per ISO/IEC
Maximum frequencyDSX-8000: 2000 MHz;
DSX-5000: 1000 MHz
General Specifications
Speed of AutotestDSX-8000: Full 2-way Autotest of Category 5e or 6/Class D or E: 7 seconds. Full 2-way Autotest of Category 6A/Class EA8 seconds. Full 2-way Autotest of Category 8: 16 seconds
DSX-5000: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds. Full 2-way Autotest of Category 6A/Class EA10 seconds
Supported test parameters (The selected test standard determines the test parameters and the frequency range of the tests)Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
Input protectionProtected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display5.7 in LCD display with a projected capacitance touchscreen
CaseHigh impact plastic with shock absorbing overmold
DimensionsMain Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
WeightMain Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)
Main unit and remote:Lithium ion battery pack, 7.2 V
Typical battery life:8 hours
Charge time*Tester off: 4 hours to charge from 10 % capacity to 90 % capacity.
Languages supportedEnglish, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian
CalibrationService center calibration period is 1 year
Integrated Wi-FiMeets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz)
Environmental Specifications
Operating Temperature32°F to 113°F (0°C to 45°C)
Storage Temperature-14°F to +140°F (-10°C to +60°C)
Operating relative humidity0 % to 90 %, 32°F to 95 °F (0°C to 35°C)
0 % to 70 %, 95°F to 113 °F (35°C to 45°C)
VibrationRandom, 2 g, 5 Hz-500 Hz
Shock1 m drop test with and without module and adapter
SafetyCSA 22.2 No. 61010, IEC 61010-1 3rd Edition
Operating altitude13,123 ft (4,000 m)
10,500 ft (3,200 m) with ac adapter
EMCEN 61326-1
Performance Specifications **
DSX-8000Category 8 test modes (or lower link categories)ANSI/TIA-1152 Level 2G
Class I/II test modesProposed standard IEC 61935-1 Ed. 5 Level VI
DSX-5000Category 6A/Class EA test modes (or lower link categories)Exceed Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1.
Class FA test modesExceed Level V requirements as in the draft 4th edition of IEC 61935-1.
Length of Twisted Pair Cabling1
 Without RemoteWith Remote
Range800 m (2600 ft)150 m (490 ft)
Resolution0.1 m or 1 ft0.1 m or 1 ft
Accuracy± (0.3 m + 2 %); 0 m to 150 m
± (0.3 m + 4 %); 150 m to 800 m
± (0.3 m + 2 %)
Propagation Delay
 Without RemoteWith Remote
Range4000 ns750 ns
Resolution1 ns1 ns
Accuracy± (2 ns + 2 %); 0 ns to 750 ns
± (2 ns + 4 %); 750 ns to 4000 ns
± (2 ns + 2 %)
Delay Skew
Range0 ns to 100 ns
Resolution1 ns
Accuracy± 10 ns
DC Loop Resistance Test
Range0 Ω to 540 Ω
Resolution0.1 Ω
Accuracy± (1 Ω + 1 %)
Overload recovery timeLess than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.

 

DOCUMENTS

Brochures

Title/DescriptionDownload 
Versiv Installation Contractor Brochure
Download PDF
1.92 MB
Unlock Icon
 
 

Data Sheets

Title/DescriptionDownload 
DSX CableAnalyzer Datasheet
Download PDFUnlock Icon
DSX Coax Datasheet
Download PDFUnlock Icon
DSX M12 Datasheet_en
DSX M12 Channel Adapters
Download PDFUnlock Icon

Copyright 2018 @ MTGlobalindo. All right reserved.

Scroll Up