Office hours

Mon - Fri 9AM-5PM

Phone

021-54314201

E-mail us

media@mtglobalindo.co.id

CertiFiber® Pro Optical Loss Test Set

Accelerates every step of the fiber certification process
  • Optical loss test set with fastest time to certify – two fibers at two wavelengths in three seconds.
  • Encircled Flux compliant as required by ANSI/TIA and ISO/IEC
  • Merged Tier 1 (Basic) / Tier 2 (Extended) testing and reporting when paired with OptiFiber® Pro OTDR
  • ProjX™ management system ensures all jobs are completed correctly and efficiently
  • Optical loss test set provides automatic Pass/Fail analysis to industry standards or custom test limits
  • Double ended Pass/Fail certification of fiber optic connector endfaces
  • Graphical indication of problem areas on fiber endfaces due to contamination, pits, chips and scratches
  • Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  • Taptive™ user interface provides simple, animated guidance to eliminate incorrect reference setup and “negative loss” errors.
  • Convenient quad module supports both multimode and singlemode loss testing
  • Extended singlemode distance range to 130km
  • Optical loss test set with built in Visual Fault Locator
  • Analyze test results and create professional test reports using LinkWare™ Management Software
  • Compatible with LinkWare™ Live. Linkware Live enables to easily track job progress, get real-time access to test results to quickly fix problems in the field, and easily transfer and consolidate test results from the tester to LinkWare™ PC Cable Test Management Software.

OVERVIEW

The CertiFiber Pro Optical Loss Test Set improves the efficiency of fiber optics certification. The Taptive user interface simplifies set-up, eliminates errors and speeds troubleshooting. A set reference wizard ensures correct reference setting and eliminates negative loss errors. Built on the future-ready Versiv platform, CertiFiber Pro Optical Loss Test Set (OLTS) provides merged Tier 1 (Basic) / Tier 2 (Extended) testing and reporting when paired with OptiFiber Pro module. A convenient quad module supports both singlemode and multimode and is multimode Encircled Flux compliant. Copper certification and Wi-Fi Analysis and Ethernet troubleshooting modules are also available. Analyze test results and create professional test reports using LinkWare Management Software.

CertiFiber Pro’s Optical Loss Test Set (OLTS) double ended fiber optic inspection capability allows you to inspect and certify fiber optic connector end-faces at both ends of your fiber link in less than a second so you can get your job done the first time. This double ended fiber optic inspection capability provides automated PASS/FAIL certification, takes the guess work out of fiber inspection so anyone can be a fiber expert.

FEATURES

Unique Features:

  • Versiv enables users to accomplish more than ever before with a cable tester, accelerating every step of the testing process
  • ProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time.
  • Taptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels.
  • LinkWare management software provides unmatched analysis of test results and professional test reports

 



Standards:

  • Allows combined OLTS Tier 1 (basic), OTDR Tier 2 (extended) certification, end-face inspection and reporting when paired with OptiFiber™ Pro OTDR
  • Set reference wizard verifies test reference cords (TRCs) per ISO/IEC 14763-3 and eliminates negative loss errors
  • Encircled Flux compliant optical launch conditions required by ANSI/TIA and ISO/IEC standards
  • Double ended fiber optic end-face certification to IEC 61300-3-35

Performance:

  • Three-second Autotest – (four times faster than legacy testers) includes optical loss measurement of two fibers at two wavelengths with distance measurement and optical loss budget calculation
  • Provides automatic Pass/Fail analysis to industry standards or custom test limits
  • Identifies incorrect test procedures resulting in negative loss results
  • Double ended Pass/Fail certification of fiber optic connector end-faces
  • Graphical indication of problem areas on fiber end-faces due to contamination, pits, chips and scratches
  • Interchangeable power meter adapters available for all typical connector types (SC, ST, LC and FC) to enable the most accurate 1-jumper reference method
  • Built-in visual fault locator for basic troubleshooting and polarity determination
  • Dual wavelength measurement capability on a single fiber allows the tester to be used in applications that require only one fiber link.
  • Compliant with TIA-526-14-B and IEC 61280-4-1 Encircled Flux requirements with no additional equipment or procedures
  • Integrated Wi-Fi allows you to easily upload results to LinkWare Live

Fiber optic connector end-face contamination is a leading cause of fiber failures. Dirt and contaminants cause insertion loss and back-reflection that inhibit optical transmission and causes havoc with transceivers. Fiber loss testing can expose this problem, but in many cases, dirty connections make fiber testing time consuming and inaccurate. Since dirt can be an issue before, during, or after fiber optic certification testing, and migrate from one fiber optic connector end-face to another upon mating, both sides of any connection must always be cleaned and inspected.

CertiFiber Pro Optical Loss Test Set (OLTS) provides double ended fiber optic inspection capability through the use of 2 Versiv Main units. One unit acts as the normal CertiFiber Pro main and the 2nd unit functions as a Remote unit. Using a Main unit as a Remote provides a touchscreen interface at the Remote end giving you the ability to visually inspect fiber end-faces!

 

CertiFiber Pro’s double ended fiber optic inspection capability allows you to inspect and certify fiber optic connector end-faces at both ends of your fiber link in less than a second so you can get your job done the first time. This double ended fiber optic inspection capability provides automated PASS/FAIL certification, takes the guess work out of fiber inspection so anyone can be a fiber expert.

Versiv’s ProjX™ System manages jobs from set-up to systems acceptance, ensuring that all tests are completed correctly. Enter the testing details for a job once, and ProjX stores them in a project file with a name the whole team can understand. Change modules or jobs without having to re-enter details. Support multiple testers on the same job by sharing project files via USB sticks or email.

 

Set-up or view test limits,
fiber types, and testing attributes.
 View multiple projects. Select a project icon to see
specific detail.



Versiv is driven by Taptive, the most advanced user interface for a field tester. With a gestured based interface, technicians and project managers of all skill levels can eliminate costly errors and do more faster with fewer key strokes, set-up wizards, swiping, pinch to zoom, and access to more data right at their fingertips.

Taptive user interface simplifies set-up,
eliminates errors and speeds troubleshooting.

Managing test results and creating professional test reports is the legacy of LinkWare, giving Project Managers full capabilities to monitor workflow and consolidate test results.

LinkWare PC pulls data together into a single report that is easy for customers to understand, showcasing quality and workmanship. LinkWare Stats feature in LinkWare PC, provides automated statistical reports that turns test results into charts to reveal performance. The report even summarizes your entire cabling and fiber infrastructure in one compact, graphical format, so it is easy to verify margins and anomalies.

Encircled Flux and Test Reference Cords Tested.

LinkWare Live is a cloud-based service that lets you manage certification jobs anytime, anywhere, with anyone on any device.  With LinkWare Live, you can

  • Keep track of every test on every job.  Get an overview of every project from any smart device. Drill down to each individual test. Instantly receive notification of incorrect test setting or cable IDs.
  • Get it right the first time. Define cable IDs and test settings from your PC or tablet. Then send them to the testers or Brother printers at the jobsite for mistake-free testing and labeling.
  • Keep your testers up to date. Standards can change without notice, and an out-of-date test report can mean hours of re-testing. LinkWare Live automatically ensures your testers are running the latest.
  • Stop wasting time and gas driving testers back to the office. Integrated Wi-Fi allows you to upload your test results straight from the job site to LinkWare Live. Then download them automatically to the right job for fast report generation with LinkWare PC.
  • Avoid Project Delays. Track the last used location and monitor the status of all testers to ensure they are always calibrated and running the latest firmware*
  • Supports all Versiv models: DSX CableAnalyzer Series, CertiFiber Pro, OptiFiber Pro, and the FI-7000.

*See supported countries.

LinkWare Live Test Result Screen for St. Peter Hospital     LinkWare Live Test Result Dashboard Screen

Models
Model Number/NameDescription
CertiFiber Pro Models

The CertiFiber Pro models are available in 2 versions: wireless and non-wireless. The Wireless version includes integrated Wi-Fi for for uploading results to LinkWare Live. The integrated Wi-FI is disabled in the non-wireless version for customers who do not wish to receive Wi-Fi.

CFP2-100-M

1 Versiv Mainframe & Remote, (2) CertiFiber Pro Multimode OLTS Modules, SC/LC EF-compliant MM TRC Kit 50 um, TRC Carrying Case, (2) LC/LC Adaptors, (2) Hand Straps, (2) Shoulder Straps, Carry Case, USB Interface Cable, Versiv Open Source Software CD, (2) AC Chargers, Integrated Wi-Fi, Statement of Calibration and Getting Started Guide.See Photo

 
CFP2-100-M-NW

Same configuration as the CFP2-100-M with integrated Wi-Fi disabled.See Photo

 
CFP2-100-S

1 Versiv Mainframe & Remote, (2) CertiFiber Pro Singlemode OLTS modules, SC/LC SM TRC Kit, TRC Carrying Case, (2) LC/LC Adaptors, (2) HandStraps, (2) Shoulder Straps, Carry Case, USB interface cable, LinkWare Software CD, Versiv Open Source Software CD, (2) AC Chargers, Integrated Wi-Fi, Statement of Calibration and Getting Started Guide.See Photo

 
CFP2-100-S-NW

Same configuration as the CFP2-100-S with integrated Wi-Fi disabled.See Photo

 
CFP2-100-Q

1 Versiv Mainframe & Remote, (2) CertiFiber Pro Quad OLTS modules, SC/LC EF-compliant MM TRC Kit 50 µm, SC/LC SM TRC Kit, TRC Carrying Case, (2) LC/LC Simplex Adaptors, (2) HandStraps, (2) Shoulder Straps, Carry Case, USB Interface Cable, Versiv Open Source Software CD, (2) AC Chargers, Integrated Wi-Fi, Statement of Calibration and Getting Started Guide. See Photo

 
CFP2-100-Q/GLD

CFP2-100-Q with 1 year of Gold Support (available in the United States and Europe. Europe order: CFP2-100-Q/GLD INT).

CFP2-100-Q-NW

Same configuration as the CFP2-100-Q with integrated Wi-Fi disabled. See Photo

 
CFP2-100-QI

CertiFiber Pro Quad OLTS with double ended inspection. This kit includes (2) Versiv Mainframes, (2) CertiFiber Pro Quad OLTS Modules, (2) USB fiber inspection video probes each with 4 tips, Multimode Encircled Flux compliant test reference cord kit (2m) for testing 50um LC terminated fibers (2 SC/LC, 2 LC/LC), Singlemode test reference cord kit (2m) for testing 9um LC terminated fibers (2 SC/LC, 2 LC/LC), TRC Carrying Case, (2) 1.25 mm Quick Clean Cleaners, (2) 2.5 mm Quick Clean Cleaners, (2) LC/LC Adaptors, (2) Hand Straps, (2) Shoulder Straps, Carry Case, USB Interface Cable, Versiv Open Source Software CD, (2) AC Chargers, Integrated Wi-Fi, Statement of Calibration and Getting Started Guide. See Photo

 
CFP2-100-QI/GLD

CFP2-100-QI CFP-100-QI with 1 year of Gold Support (available in the United States and Europe. Europe order: CFP2-100-QI/G INT).

CFP2-Q-ADD-R

CertiFiber Pro Add on Kit with Remote – includes 1 Versiv 2 Remote, (2) CertiFiber Pro Quad OLTS modules, SC/LC EF-compliant MM TRC Kit 50 µm, SC/LC SM TRC Kit, TRC Carrying Case, (2) LC/LC Simplex Adaptors, (2) HandStraps, (2) Shoulder Straps, Large Carry Case, AC Chargers, Statement of Calibration and Getting Started Guide. (Requires a Versiv 2 mainframe) See Photo

 
CFP-Q-ADD

CertiFiber Pro Add on Kit – includes (2) CertiFiber Pro Quad OLTS Modules, SC/LC EF-compliant MM TRC Kit 50 µm, SC/LC SM TRC Kit, TRC Carrying Case, (2) LC/LC Simplex Adaptors, Large Carry Case, Versiv Open Source Software CD, Statement of Calibration and Getting Started Guide. See Photo

 
CFP-MM-ADD

(2) CertiFiber Pro Multimode OLTS Modules, SC/LC EF-compliant MM TRC Kit 50 µm, TRC Carrying Case, (2) LC/LC Adaptors, Large Carry Case, Statement of Calibration and Getting Started Guide. See Photo

 
CFP-SM-ADD

(2) CertiFiber Pro Singlemode OLTS Modules, SC/LC SM TRC Kit, TRC Carrying Case, (2) LC/LC Adaptors, Large Carry Case, Statement of Calibration and Getting Started Guide. See Photo

 
 
Accessories
Model Number/NameDescription
CFP-MM-ModCERTIFIBER PRO multimode replacement module
CFP-SM-ModCERTIFIBER PRO singlemode replacement module
CFP-QUAD ModCERTIFIBER PRO quad replacement module
FI-1000-KIT

A USB Fiber Inspection Video probe for Versiv products plus tip set (LC, FC/SC bulkhead, 1.25 and 2.5mm universal tips in a box). See Photo

 
FI1000

FI-1000 FiberInspector USB video probe for Versiv platform.

FI1000-SCFC-TIPSC and FC bulkhead video probe tip. See Photo
FI1000-LC-TIPLC bulkhead video probe tip. See Photo
FI1000-EXND-LC-TIP

Extended LC bulkhead video probe tip. See Photo

FI1000-ST-TIPST bulkhead video probe tip. See Photo
FI1000-MU-TIPMU bulkhead video probe tip. See Photo
FI1000-E2KAPC-TIP

E2000/APC bulkhead video probe tip. See Photo

FI1000-SCAPC-TIPSC/APC bulkhead video probe tip. See Photo
FI1000-E2K-TIPE2000 bulkhead video probe tip. See Photo
FI1000-LCAPC-TIP

LC/APC bulkhead video probe tip. See Photo

FI1000-2.5-UTIP2.5 mm universal video probe tip for patch cords. See Photo
FI1000-LC-PCTIPVideo probe tip for LC simplex and duplex connectors. See Photo
FI1000-2.5APC-UTIP2.5 mm APC universal video probe tip for patch cord. See Photo
FI1000-MPO-UTIPMPO probe tip and translator knob for patch cords and bulkheads
FI1000-MPO-XY-UTIPMPO probe tip and translator knob for multi-row patch cords and bulkheads
FI1000-MPOAPC-UTIPMPO/APC probe tip and translator knob for patch cords and bulkheads. See Photo
FI1000-MPOAPC-XYMPO/APC probe tip and translator knob for multi-row patch cords and bulkheads. See Photo
FI1000-1.25APC-TIP1.25 mm APC universal video probe tip for patch cords. See Photo
FI1000-MPOAPC-RTMPO/MTP APC REPLACEMENT TIP WITH NO TRANSLATOR KNOB
FI1000-MPO-RTMPO/MTP REPLACEMENT TIP WITH NO TRANSLATOR KNOB
FI1000-TIP-KITLC,FC/SC BULKHEAD, 1.25 AND 2.5MM UNIVERSAL TIPS IN A BOX
NFC-Kit-Case-E

Enhanced Fiber Optic Cleaning Kit – Includes a Quick Clean 1.25mm cleaner, a Quick Clean 2.5mm cleaner, a Quick Clean MPO cleaner, a solvent pen, a cleaning cube and a softcase See Photo

SRC-9-SCSC-KIT

Singlemode test reference cord kit (2m) for testing SC terminated fibers (4 SC/SC)

SRC-9-SCLC-KIT

Singlemode test reference cord kit (2m) for testing LC terminated fibers (2 SC/LC, 2 LC/LC) See Photo

SRC-9-SCFC-KITSinglemode test reference cord kit (2m) for testing FC terminated fibers (2 SC/FC, 2 FC/FC)
SRC-9-SCST-KITSinglemode test reference cord kit (2m) for testing ST terminated fibers (2 SC/ST, 2 ST/ST)
SRC-9-SCSCAPCKITSinglemode TRC KIT 2m (2 SCUPC/SCAPC,2 SCAPC/SCAPC)
SRC-9-SCLCAPCKITSinglemode TRC KIT 2m (2 SCUPC/LCAPC,2 LCAPC/LCAPC)
SRC-9-SCE2KAPCKITSinglemode TRC KIT 2m (2 SCUPC/E2KAPC, 2 E2KAPC/E2KAPC)
SRC-9-SCSCSinglemode test reference cord (2m) for testing SC terminated fibers (SC/SC)
SRC-9-SCLCSinglemode test reference cord (2m) for testing LC terminated fibers (SC/LC)
SRC-9-SCFCSinglemode test reference cord (2m) for testing FC terminated fibers (SC/FC)
SRC-9-SCSTSinglemode test reference cord (2m) for testing ST terminated fibers (SC/ST)
SRC-9-LCLCSinglemode test reference cord (2m) for testing LC terminated fibers (LC/LC)
SRC-9-FCFCSinglemode test reference cord (2m) for testing FC terminated fibers (FC/FC)
SRC-9-STSTSinglemode test reference cord (2m) for testing ST terminated fibers (ST/ST)
MRC-50EFC-SCLCKIT

Multimode Encircled Flux compliant test reference cord kit (2m) for testing 50um LC terminated fibers (2 SC/LC, 2 LC/LC)

MRC-50EFC-SCSCKITMultimode Encircled Flux compliant test reference cord kit (2m) for testing 50um SC terminated fibers (4 SC/SC)
MRC-50EFC-SCSTKITMultimode Encircled Flux compliant test reference cord kit (2m) for testing 50um ST terminated fibers (2 SC/ST, 2 ST/ST)
MRC-50EFC-SCFCKITMultimode Encircled Flux compliant test reference cord kit (2m) for testing 50um FC terminated fibers (2 SC/FC, 2 FC/FC)
MRC-50-EFC-SCSCMultimode Encircled Flux compliant test reference cord (2m) for testing 50um SC terminated fibers (SC/SC)
MRC-50-EFC-SCLC

Multimode Encircled Flux compliant test reference cord (2m) for testing 50um LC terminated fibers (SC/LC)

MRC-50-EFC-SCFCMultimode Encircled Flux compliant test reference cord (2m)for testing 50um FC terminated fibers (SC/FC)
MRC-50-EFC-SCSTMultimode Encircled Flux compliant test reference cord (2m) for testing 50um ST terminated fibers (SC/ST)
MRC-625EFC-SCLCKIT

Multimode Encircled Flux compliant test reference cord kit (2m) for testing 62.5um LC terminated fibers (2 SC/LC, 2 LC/LC)

MRC-625EFC-SCSCKIT

Multimode Encircled Flux compliant test reference cord kit (2m) for testing 62.5um SC terminated fibers (4 SC/SC)

MRC-625EFC-SCSTKITMultimode Encircled Flux compliant test reference cord kit (2m) for testing 62.5um ST terminated fibers (2 SC/ST, 2 ST/ST)
MRC-625EFC-SCFCKITMultimode Encircled Flux compliant test reference cord kit (2m) for testing 62.5um FC terminated fibers (2 SC/FC, 2 FC/FC)
MRC-625-EFC-SCSCMultimode Encircled Flux compliant test reference cord (2m) for testing 62.5um SC terminated fibers (SC/SC)
MRC-625-EFC-SCLCMultimode Encircled Flux compliant test reference cord (2m) for testing 62.5um LC terminated fibers (SC/LC)
MRC-625-EFC-SCFCMultimode Encircled Flux compliant test reference cord (2m)for testing 62.5um FC terminated fibers (SC/FC)
MRC-625-EFC-SCSTMultimode Encircled Flux compliant test reference cord (2m) for testing 62.5um ST terminated fibers (SC/ST)
MRC-50-SCSCMultimode test reference cord (2m) for testing 50µm SC terminated fibers (SC/SC)
MRC-50-LCLCMultimode test reference cord (2m) for testing 50µm LC terminated fibers (LC/LC)
MRC-50-FCFCMultimode test reference cord (2m)for testing 50µm FC terminated fibers (FC/FC)
MRC-50-STSTMultimode test reference cord (2m) for testing 50µm ST terminated fibers (ST/ST)
MRC-625-SCSCMultimode test reference cord (2m) for testing 62.5µm SC terminated fibers (SC/SC)
MRC-625-LCLCMultimode test reference cord (2m) for testing 62.5µm LC terminated fibers (LC/LC)
MRC-625-FCFCMultimode test reference cord (2m)for testing 62.5µm FC terminated fibers (FC/FC)
MRC-625-STSTMultimode test reference cord (2m) for testing 62.5µm ST terminated fibers (ST/ST)
TRC-CASECarrying Case for Test Reference Cords
NFA-SCSet of 2 SC Interchangeable Adapters for CFP power meter port
NFA-LCSet of 2 LC Interchangeable Adapters for CFP power meter port.
NFA-STSet of 2 ST Interchangeable Adapters for CFP power meter port
NFA-FCSet of 2 FC Interchangeable Adapters for CFP power meter port
NFA-E2k-SingleE2000 Interchangeable adapter for CFP power meter port, qty 1
ADP-LC/APCLC-APC simplex adapter
ADP-SC/APCSC-APC simplex adapter
ADP-E2K/APCE2K-APC simplex adapter
VERSIV2-MVERSIV2 MAIN REPLACEMENT W/WIFI
VERSIV2-RUVERSIV2 REMOTE REPLACEMENT
VERSIV-TSET

Versiv Headphones See Photo

TFS-USB-CBLUSB interface cable standard A to micro B
VERSIV-BATTERY

Versiv Battery See Photo

PWR-SPLY-30W30W Power Supply, 15V, 2A with US adapter. See Photo
PWR-SPLY-30W INTL

30W Power Supply, 15V, 2A with US, EU, AU, and UK adapters See Photo

PWR-SPLY-30W SA/IN

30W Power Supply, 15V, 2A with US, South Africa and India adapters See Photo

PWR-SPLY-ADPEU, AU, UK adapters for 30W power supply. See Photo
PWR-SPLY-ADP-SA

South Africa and India adapters for 30W power supply See Photo

VERSIV-STRP

Versiv Strap Kit See Photo

VERSIV-STNDVersiv Demo Stand
VERSIV-ADP-WIFI

WiFi Adapter for Versiv Mainframe. (Available in the following countries.)

VERSIV-CASE3

VERSIV Hardsided Case See Photo

VERSIV-LG-CASE

Versiv Large Carry Case See Photo

VERSIV-SM-CASE

Versiv Small Carry Case. See Photo

VERSIV-BACKPK-STRP

Backpack strap for Versiv Large Case See Photo

SPECIFICATIONS

Power Meter Specifications
Input ConnectorInterchangeable connector adapter (LC standard, SC, ST and FC optional)
Detector TypeInGaAs
Wavelengths850 nm, 1300 nm, 1310 nm, 1550 nm
Power Measurement Range0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
Power Measurement Uncertainty1,2< +/- 5% +/- 32 pW
Measurement Linearity3< ± 0.1 dB
Re-calibration Period1 year
Integrated Wi-FiMeets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz)
1. +/- 100 pW at 850 nm
2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50/125 μm and NA = 0.14 for 9/125 μm. Ambient temperature 23° ± 1°C. SC/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST.
3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5 minute warm-up.
Loss/Length Specifications
SpecificationCertiFiber Pro Multimode ModulesCertiFiber Pro Singlemode Modules
Testing Speeds (excludes referencing times)Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection)
Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
Input/Output ConnectorsInterchangeable connector adapter (LC standard, SC, ST and FC optional)
Launch Condition1,2Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1
Fiber Types Tested50/125 µm or 62.5/125 µmsinglemode
Source Type and WavelengthsLED source 850 nm ± 30 nm 1300 nm ± 20 nmFabry-Perot laser diode 1310 nm ± 20 nm 1550 nm ± 30 nm
Maximum Length Measurement12 km130 km
Length Measurement Accuracy± 1.5 m plus ± 1 % of length± 1.5 m plus ± 1 % of length
Output Power (Nominal)≥ -24 dBm with EF-TRC≥ -4 dBm
Output Power Stability3± 0.05 dB over 8 hours ± 0.03 dB over 15 minutes± 0.1 dB over 8 hours ± 0.08 dB over 15 minutes
1. At the output of the EF-TRC
2. Variations between EF measurement equipment may occur but EF compliance can be expected with a 95% confidence factor
3. Relative to power level after 15 minute warm up – at constant temperature
Loss/Length Specifications (continued)
Source Wavelengths850 nm, 1300 nm, 1310 nm, 1550 nm
Power Measurement Range0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
Power Measurement Uncertainty1, 2< +/- 5% +/- 32 pW
Measurement Linearity3< ± 0.1 dB
Re-calibration Period1 year
1. +/- 100 pW at 850 nm
2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50/125 μm and NA = 0.14 for 9/125 μm. Ambient temperature 23° ± 1°C. SC/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST.
3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5-minute warm-up.
Selected Specifications
Visual Fault Locator (VFL)
TitleRequirement
Output Power>-5 dBm
<0 dBm
SMF-28 singlemode fiber
Continuous wave
SC/UPC connector
Operating Wavelength650 nm nominal
Output ModesContinuous wave
Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector Adapter2.5 mm universal
Laser SafetyClass II CDRH
Over operating temperature range
Environmental Specifications
TitleRequirement
Operating Temperature-10° C to 45° C
Storage Temperature-10° C to +60° C

Operating Relative Humidity

% RH without condensation

0 % to 90 %, 32 °F to 95 °F (0° C to 35° C)
0 % to 70 %, 95 °F to 113 °F (35° C to 45° C)
VibrationRandom, 2 g, 5 Hz-500 Hz
Shock1 m drop test with and without module and adapters
SafetyCSA C22.2 No. 1010.1: 1992
EN 61010-1 1st Edition + Amendments 1, 2
Pollution Degree2
AltitudeOperating: 4,000 m; storage: 12,000 m
EMCEN 61326–1

 

DOCUMENTS

Brochures

Title/DescriptionDownload 
Versiv Installation Contractor Brochure
Download PDF
1.92 MB
Unlock Icon
 
 

Data Sheets

Title/DescriptionDownload 
Certifiber Pro OLTS Datasheet
Download PDFUnlock Icon
 
 